Ritar FT12-160A · 160Ah 12V · backup battery for UPS, alarm panels and telecom racks
Ritar FT12-160A for UPS and standby systems · listed by code. Voltage 12V.
- Nominal voltage: 12V
- Capacity, 10-hour rate (C10): 160Ah
- Dimensions (L × W × H): 565 × 110 × 296 mm
- Chemistry: AGM
In short: The battery on this page is the Ritar FT12-160A, aimed at UPS and standby systems. Terminal position is the detail people most often forget.
About the Ritar FT12-160A
UPS, alarm or emergency light needing a Ritar FT12-160A? Read on. Sealed construction lets it sit in a cabinet for years. Ordering batteries online suits planned replacement cycles in offices and buildings.
Rated 160Ah, it offers more capacity than the typical battery for UPS and standby systems.
Ritar FT12-160A data sheet
| Manufacturer | Ritar |
| Model code | FT12-160A |
| Series | RITAR FT |
| Application | UPS and standby systems |
| Nominal voltage | 12V |
| Capacity, 10-hour rate (C10) | 160Ah |
| Chemistry | AGM |
| Dimensions (L × W × H) | 565 × 110 × 296 mm |
| Weight | 49 kg |
| Terminals | M8 |
Installation and maintenance tips
Data centres replace whole strings of batteries on a schedule. Replace every battery in a UPS string at once with identical units. A UPS that shuts down seconds after a cut needs new batteries.
About the technology: AGM
Each AGM cell is packed so tightly that the plates barely move, even on a bumpy road. Leisure vehicles choose AGM when the battery lives under a seat. A battery tester gives a clearer picture of AGM health than a voltmeter.
Will the Ritar FT12-160A fit?
- ✓ A case of 565 × 110 × 296 mm must sit flat with the clamp closed.
- ✓ 160Ah sets how long the battery can power things with the engine off.
- ✓ These are M8 terminals. Photograph the old ones before ordering to compare side by side.
Questions buyers ask about the Ritar FT12-160A
What range does the Ritar FT12-160A come from?
This reference sits within RITAR FT. Browse the brand page to see the neighbouring sizes of the same range.
Is this the right replacement for my current battery?
The safest test is a direct comparison: same voltage, same or slightly higher capacity, same case size and the same terminal orientation. Your owner's manual usually lists the original values.
Can I order a battery for UPS and standby systems at baterias.online?
Only a few minutes once you have checked the figures and the code.
Which code identifies my existing battery?
Usually on the top label or the front of the case, near the logo. Search for brand plus that code.
Explore more
Everything you need to order the Ritar FT12-160A is on this page. Checking the data first saves the hassle of a wrong order.